11–16 May 2014
Casino Conference Centre
Europe/Prague timezone

The matrix influence on the determination of low uranium concentrations

13 May 2014, 17:15
1h 30m
Gallery (Casino Conference Centre)

Gallery

Casino Conference Centre

Reitenbergerova 4/95, Mari&#225;nsk&#233; L&#225;zn&#283;, Czech Republic <font color=white>
Poster Radionuclides in the Environment, Radioecology Poster Session - Radionuclides in the Environment, Radioecology

Speaker

Dr Alena Zavadilova (Czech Technical University in Prague, Faculty of Nuclear Sciences and Physical Engineering)

Description

We refer about a development of the measurement technique enabling the determination of low uranium concentrations. The method was inspired by a commercially available KPA method (kinetic phosphorescence analysis). It is fast, sensitive, and non-destructive, allowing the uranium concentrations determination on a mass basis of μg U/l. Contrary to the conventional KPA method it is in our approach not necessary to use an external standard as a reference sample. Moreover the solid state laser is used instead of nitrogen or dye laser and thus no dye solution preparation is required and no laser tube degradation appears. As an excitation source we use the solid state tunable laser, commonly utilized for TRLFS (time resolved laser induced fluorescence spectroscopy) measurement, operating at 416 nm for which the uranium complex fluorescence signal has the highest intensity. Excitation energy was 4.5 mJ. The fluorescence spectra were recorded using the grating monochromator followed by an ICCD camera. To eliminate the influence of possible excitation energy fluctuation on the measured fluorescence intensities, each recorded spectra were normalized with respect to this energy. For every sample ten measurements with 200 acquisitions were realized (the overall acquisition time was ~3 min). Besides the intensity measurement the method enables the study of the emission spectral characteristic and the detail measurement of complexes wavelength shift. Because the fluorescence is strongly temperature-dependent, the temperature of the sample was controlled and stabilized. In our laboratory, the concentration of uranium is determined mainly in samples resulting from the leachates of rock and sediment materials and of surface water. Therefore we have focused on verifying the applicability of our method for samples with such matrix that could significantly influences the determination of uranium concentration. For that reason we studied the influence of the particular matrix, complexing agent, and the sample pH on the recorded fluorescence spectrum shape and integral intensity. The uranium concentration in samples ranged from 1 to 1000 μg/l. To acidify the samples the HNO3 was used. To limit the quenching effect and to prolong the UO22+ life-time, a complexing agent URAPLEX or optionally more available H3PO4 was added. We can conclude that for most of the investigated matrixes the described method offered sufficient precision of the uranium concentration determination. On the other side, it was found that the presence of nitrates and chlorides could be problematical. Especially in case of nitrates even the method of standard addition did not offered satisfying results. This behavior is under further investigation.

Primary author

Dr Alena Zavadilova (Czech Technical University in Prague, Faculty of Nuclear Sciences and Physical Engineering)

Co-authors

Dr Barbora Drtinova (Czech Technical University in Prague, Faculty of Nuclear Sciences and Physical Engineering) Dr Dusan Vopalka (Czech Technical University in Prague, Faculty of Nuclear Sciences and Physical Engineering)

Presentation materials