Jun 7โ€‰โ€“โ€‰11, 2026
Prague, Czechia
Europe/Prague timezone

Session

Poster session

Jun 8, 2026, 5:45โ€ฏPM
CTU in Prague, Faculty of Nuclear Sciences and Physical Engineering (Prague, Czechia)

CTU in Prague, Faculty of Nuclear Sciences and Physical Engineering

Prague, Czechia

Bล™ehovรก 78/7 115 19 Prague 1 Czech Republic GPS. 50.0910372N, 14.4163028E

Presentation materials

There are no materials yet.

  1. Dr Rong-Jiun Sheu (National Tsing Hua University)
    6/8/26, 5:45โ€ฏPM
    Basic concepts and principles in dosimetry
    Poster

    The National Radiation Standard Laboratory (NRSL/INER) established a primary standard for the reference air kerma rate (RAKR) of HDR Ir-192 brachytherapy sources based on dual graphite-walled spherical cavity ionization chambers combined with a dedicated dual-collimator geometry. The original realization achieved an expanded uncertainty of 0.92% (k = 2) and demonstrated consistency in the...

    Go to contribution page
  2. Patricia Mayo (ISIRYM,Universitat Politรจcnica de Valรจncia)
    6/8/26, 5:47โ€ฏPM
    Computational methods and modelling in dosimetry
    Poster

    Introduction:
    Understanding how parameter variability influences occupational dose is essential for radiological protection during nuclear decommissioning. This study performs a detailed sensitivity and uncertainty analysis of the effective dose received by an Industrialโ€‘Worker scenario at a decommissioned PWR facility, using RESRADโ€‘ONSITE as the computational dosimetry...

    Go to contribution page
  3. JOSร‰ NERES DE ALMEIDA JUNIOR (IPEN/CNEN - USP/SP), Maria da Penha Potiens (Instituto de Pesquisas Energรฉticas e Nucleares)
    6/8/26, 5:49โ€ฏPM
    Computational methods and modelling in dosimetry
    Poster

    Ensuring international metrological traceability for Air Kerma-Area Product (PKA) measurements is crucial for modern clinical dosimetry. Traditional calibration methods have limitations in geometry, uncertainty, and clinical deployment. This study proposes a hybrid methodology to establish a robust traceability chain for PKA meters. To develop and validate a computational protocol for the PKA...

    Go to contribution page
  4. GABRIEL NASCIMENTO (Instituto de Pesquisas Energรฉticas e Nucleares)
    6/8/26, 5:51โ€ฏPM
    Basic concepts and principles in dosimetry
    Poster

    In recent years, eye lens dosimetry has been the subject of numerous studies, many motivated by the changes implemented by the ICRP in Publication 108. Front-line professionals in interventional radiology, particularly radiologists, are exposed to high doses to the eye lens. This study evaluates the performance of a new dosimeter holder for the quantity Hpโ€‹(3), manufactured via 3D printing...

    Go to contribution page
  5. bruno chaves dos santos
    6/8/26, 5:53โ€ฏPM
    Computational methods and modelling in dosimetry
    Poster

    This work aims to present a methodological and modeled way to extract, treat and apply physics in CT dosimetry studies to obtain relevant and statistical parameters such as absorbed dose, kvp and tube current. Anonymized Computed Tomography studies hosted in the various websites of medicine and nuclear medicine was used as a primary tool in order to employ the physics of attenuation of primary...

    Go to contribution page
  6. Jaroslav Klusoลˆ (Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague), Vรกclav ล tฤ›pรกn (Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague)
    6/8/26, 5:55โ€ฏPM
    Computational methods and modelling in dosimetry
    Poster

    Airborne gamma spectrometry measures desired radiation quantities usually from relatively long distances, often from sources spread over large areas. Values measured over one data acquisition period (scan) represent the average over a specific area and, in general, may not agree with the value at the corresponding coordinates on the surface. This โ€œspatial resolutionโ€ depends on the height and...

    Go to contribution page
  7. Cristina Trull-Hernandis (Universitat Politรจcnica de Valรจncia)
    6/8/26, 5:57โ€ฏPM
    Radiation detection and spectrometry
    Poster

    The radiological characterization of building materials is essential to evaluate their potential contribution to indoor radon levels and to better understand the mechanisms governing radon release from building products. In this context, both the intrinsic radioactive content of raw materials and their final physical state may influence radon exhalation behavior.
    This work presents an...

    Go to contribution page
  8. Dr Rong-Jiun Sheu (National Tsing Hua University)
    6/8/26, 5:59โ€ฏPM
    Radiation detection and spectrometry
    Poster

    This study optimizes the performance of a stainless-steel, 2ฯ€ windowless large-area multi-wire proportional counter at the National Ionizing Radiation Standard Laboratory (NRSL) in Taiwan. Featuring a 100 mmร— 150 mm effective area and a NIM-standard analog processing chain, the system utilizes P-10 gas for particle detection via ionization and charge multiplication. By employing absolute...

    Go to contribution page
  9. Dr Aleลก Janฤรกล™ (BERTIN VF NUCLEAR)
    6/8/26, 6:01โ€ฏPM
    Radiation detection and spectrometry
    Poster

    The newly developed nuclear spectrometric system incorporates a digital multichannel analyzer, suitable radiation detectors, and advanced algorithms for the characterization of unknown fast neutron fields. Accurate knowledge of these fields is essential for the objective assessment of the metrological performance of neutron devices during calibration.
    The hardware platform of the system is...

    Go to contribution page
  10. Ademar Josรฉ Potiens Jรบnior, Maria da Penha Potiens (Instituto de Pesquisas Energรฉticas e Nucleares), Raphael Elias Diniz
    6/8/26, 6:03โ€ฏPM
    Radiation detection and spectrometry
    Poster

    The calibration of surface contamination monitors requires the use of Large Area Reference Sources (LAAS) whose emission properties must strictly comply with the ISO 8769 standard. A critical requirement of this standard is the uniformity of the surface emission rate, which must be periodically verified to ensure measurement traceability. Currently, the lack of dedicated national...

    Go to contribution page
  11. Dr Ademar Potiens Junior (Instituto de Pesquisas Energรฉticas e Nucleares (IPEN)), Mr Fabio Bessa Villafranca (Instituto de Pesquisas Energรฉticas e Nucleares (IPEN)/ Universidade de Sรฃo Paulo (USP))
    6/8/26, 6:05โ€ฏPM
    Radiation detection and spectrometry
    Poster

    The Waste Management Department (SEGRR) in the Nuclear and Energy Research Institute (IPEN), Sรฃo Paulo, Brazil, is responsible for managing radioactive waste produced in its facilities and also in the southeastern region of Brazil. Among those wastes are the compactable solid waste, stored in 200-liter drums at IPEN interim storage site. It is estimated that the content of 256 of those drums...

    Go to contribution page
  12. Hana Prลฏลกovรก (CVUT, FJFI, KDAIZ)
    6/8/26, 6:07โ€ฏPM
    Radiation detection and spectrometry
    Poster

    The full-field X-ray fluorescence (XRF) imaging offers a possibility to create high-resolution 2D elemental maps of a measured sample at once without the need for the sequential scanning of the sample surface with a narrow X-ray beam.
    Our setup for full-field XRF imaging utilises low-power X-ray tubes and Color X-ray Camera (CXC) spectrometric pixel detector with a capillary collimator. This...

    Go to contribution page
  13. Vรกclav ล tฤ›pรกn (Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague)
    6/8/26, 6:09โ€ฏPM
    Dosimetry in radiological and nuclear emergencies and accidents
    Poster

    Important part of radiological emergency response training is radiological assessment of the site and delineation of cold/warm/hot zones. Ideally, the training would be a hands-on practice with real radiation sources with type, activity and spatial distribution matching the modelled emergency situation. However, such training is constrained by safety, regulatory and logistical limitations....

    Go to contribution page
  14. Michael Discher (Paris Lodron University Salzburg)
    6/8/26, 6:11โ€ฏPM
    Dosimetry in radiological and nuclear emergencies and accidents
    Poster

    Retrospective dosimetry requires readily available materials with reliable luminescent responses to ionizing radiation when personal dosimeters are absent. Preliminary studies (ลepkowska and Jung, 2024, 2022; Fattibene et al., 2022) have highlighted the potential of mobile phone glass for retrospective dosimetry. However, a systematic investigation is still needed to establish a comprehensive...

    Go to contribution page
  15. Andrej Gvozdic (Czech Technical University in Prague)
    6/8/26, 6:13โ€ฏPM
    Dosimetry and radiation protection in industry
    Poster

    Weld characterization requires both compositional and structural information, yet conventional X-ray diffraction (XRD) and X-ray fluorescence (XRF) are typically performed sequentially, increasing acquisition time and complicating spatial correlation. In this work, we demonstrate spatially resolved, simultaneous XRD and XRF analysis of welded metal plates using a pnCCD-based Color X-ray Camera...

    Go to contribution page
  16. Prof. Fang-Yuh Hsu (National Tsing Hua University)
    6/8/26, 6:15โ€ฏPM
    Dosimetry and radiation protection in industry
    Poster

    Handheld X-ray Fluorescence (XRF) analyzers are widely utilized in metal recycling, environmental soil monitoring, and hazardous substance screening due to their advantages in non-destructive, real-time qualitative and quantitative analysis. However, the ionizing radiation generated by the internal X-ray tube during operation poses potential health risks to operators. This study investigates...

    Go to contribution page
  17. VIVIANE ASFORA (UFPE)
    6/8/26, 6:17โ€ฏPM
    Dosimetry and radiation protection in industry
    Poster

    The Sterile Insect Technique (SIT) is based on the release of irradiated males to suppress insect populations through induced sterility. The success of this approach depends on the accurate delivery and verification of absorbed dose, ensuring effective sterilization while preserving insect quality and mating competitiveness. In this context, reliable dosimetry systems are essential for...

    Go to contribution page
  18. Michael Hajek (International Atomic Energy Agency)
    6/8/26, 6:19โ€ฏPM
    Personnel dosimetry and monitoring
    Poster

    The quality of individual monitoring services depends on the characteristics of the type-tested dosimetry system, personnel competence, and the robustness of calibration procedures and quality assurance programmes. While type testing establishes system performance under varied conditions, routine performance testing ensures sustained accuracy and reliability under representative workplace...

    Go to contribution page
  19. Dr Lenin E. Cevallos-Robalino (Carrera de Ingenierรญa en Mecatrรณnica, Grupo de Investigaciรณn en Micro-Nanotecnologรญa y Energรญa Nuclear (NANOTECH), Universidad Politรฉcnica Salesiana (UPS), C. Robles 107 Chambers, 090108, Guayas, Guayaquil, Ecuador)
    6/8/26, 6:21โ€ฏPM
    Personnel dosimetry and monitoring
    Poster

    A comprehensive spectral and dosimetric assessment of a thermoluminescent neutron personal dosimetry system was performed using Monte Carlo simulations to reproduce reference irradiation conditions at the Neutron Standards Laboratory (LPN-CIEMAT, Spain). The system, composed of paired TLD-600 and TLD-700 detectors, was positioned on the surface of an ISO water phantom and exposed to a...

    Go to contribution page
  20. Jana Hudzietzovรก (Faculty of Biomedical Engineering, Czech Technical University in Prague, CZECH REPUBLIC)
    6/8/26, 6:23โ€ฏPM
    Personnel dosimetry and monitoring
    Poster

    Introduction: In recent years, the number of workplaces providing lutetium therapy has increased, which is one of the modern therapeutic procedures of nuclear medicine โ€“ theragnostic, combining not only therapy with radiopharmaceuticals but also diagnostics. This therapy can be administered in the inpatient part of the workplace as well as in an outpatient manner. In the outpatient method of...

    Go to contribution page
  21. Eleni Papadomarkaki (GREEK ATOMIC ENERGY COMMISSION (EEAE))
    6/8/26, 6:25โ€ฏPM
    Personnel dosimetry and monitoring
    Poster

    This study presents a bibliometric analysis of research trends in eye lens dosimetry for occupational exposure. A search in the Scopus database for the last two decades identified 353 articles that met our selection criteria. Bibliometric networks and trends were examined using VOSviewer to explore publication dynamics, geographic distribution, institutional collaboration, and thematic...

    Go to contribution page
  22. Dr Ying-Lan Liao (National Atomic Research Institute)
    6/8/26, 6:27โ€ฏPM
    Personnel dosimetry and monitoring
    Poster

    Background and Objective: Following the ICRP recommendation to lower the occupational eye lens equivalent dose limit to 20 mSv/year, accurate Hp(3) monitoring has become a critical priority. our study evaluates the performance of commercial eye lens dosimeters by comparing national proficiency testing results under two distinct international standards.
    Materials and Methods: Ten dosimetry...

    Go to contribution page
  23. Jozef Sabol (Police Academy of the Czech Republic in Prague)
    6/8/26, 6:29โ€ฏPM
    Other topics related to ionizing radiation
    Poster

    At present, there are too many quantities used in radiation protection, which are causing some problems and inconsistencies in the presentation and interpretation of results from radiation detection and monitoring. Furthermore, the definition of these quantities is rather complicated and difficult to understand, especially for those entering the field. Another problem is the availability of...

    Go to contribution page
  24. M. Hiller (RadCon GmbH, Augsburg, Germany)
    6/8/26, 6:31โ€ฏPM
    Personnel dosimetry and monitoring
    Poster

    Lithium fluoride (LiF) thermoluminescent dosemeters (TLD) are commonly used for personnel monitoring. When the TL material is enriched in $^6$Li they are sensitive to neutrons via the $^6$Li(n,$\alpha$)$^3$H reaction which has a strong energy dependence. These dosemeters are referred to as albedo dosemeters since they rely on neutrons that are backscattered from the body (or phantom) and these...

    Go to contribution page
  25. Mr Jozef Sabol (Police Academy of the CR in Prague, Czech Republic)
    6/8/26, 6:33โ€ฏPM
    Other topics related to ionizing radiation
    Poster

    Introduction: Communication of radiation risk arising from the use of radiation and nuclear technologies for various purposes is an important part of protecting all persons who are, or may be, affected by radiation exposure during the application of these technologies under normal conditions and in emergency situations, including terrorist attacks. This danger may include not only the members...

    Go to contribution page
  26. Ademar Josรฉ Potiens Jรบnior
    6/8/26, 6:35โ€ฏPM
    Other topics related to ionizing radiation
    Poster

    In the nuclear energy sector, adherence to safety standards is paramount for operational efficiency and radiological protection. However, the exponential growth of technical documents issued by the International Atomic Energy Agency (IAEA) and the Brazilian National Commission for Nuclear Energy (CNEN) has made efficient information retrieval a critical challenge. Traditional keyword-based...

    Go to contribution page
  27. Mr Vรกclav Prochรกzka (KDAIZ, FJFI ฤŒVUT v Praze)
    6/8/26, 6:37โ€ฏPM
    Other topics related to ionizing radiation
    Poster

    X-Ray Fluorescence with sufficient spatial resolution is an efficient non-destructive tool for mapping the distribution of several elements in dendrochronological samples as a probe into uptake of these elements during the tree growth. Here we present an example of secondary penetration of metals, arsenic and sulfur into wood from archaeological findings south of the town Havlรญฤkลฏv Brod. Fir...

    Go to contribution page
  28. Aljawhara Almuqrin (Princess Nourah bint Abdulrahman University)
    6/8/26, 6:39โ€ฏPM
    Other topics related to ionizing radiation
    Poster

    Tellurite-based glasses are promising candidates for ionizing radiation shielding due to their high density, good transparency, and compositional flexibility. In this work, a series of TeOโ‚‚โ€“Bโ‚‚Oโ‚ƒโ€“PbOโ€“M glasses (where M = SrO, BaO, MgO, and CaO) were successfully fabricated using the conventional melt-quenching technique, and the influence of the modifier oxide (M) on the gamma-ray shielding...

    Go to contribution page
  29. Ms Celia Tendero (Universitat Politรจcnica de Valรจncia), Ms Mรณnica Chillarรณn (Universitat Politรจcnica de Valรจncia), Mr Vicente Vidal (Universitat Politรจcnica de Valรจncia)
    6/8/26, 6:41โ€ฏPM
    Other topics related to ionizing radiation
    Poster

    Radiographic imaging is an essential diagnostic tool in medicine, but repeat exposure to radiation does not come without hazards. The acquisition of good quality images depends on the use of high energy on the X-Ray tube. Lowering that energy reduces the dose administered, however reducing X-Ray tube current and voltage can introduce Poisson noise in the images and the image exposure. With the...

    Go to contribution page
  30. Dr Rong-Jiun Sheu (National Tsing Hua University)
    6/8/26, 6:43โ€ฏPM
    Radiation detection and spectrometry
    Poster

    In digital triple-to-double coincidence ratio (TDCR) measurement systems, optical integrity and gain stability of photomultiplier tubes (PMTs) are essential to ensure reliable efficiency modelling and reproducibility of the T/D ratio. A modular portable digital TDCR system incorporating an integrated mechanical shutter and pneumatically actuated sealing mechanism was developed to enable mobile...

    Go to contribution page
  31. Carles Domingo (Universitat Autonoma de Barcelona)
    6/8/26, 6:45โ€ฏPM
    Radiation detection and spectrometry
    Poster

    Neutron personal dosimetry is essential for monitoring workers exposed to neutron radiation, from those in the nuclear industry to surgeons and other healthcare professionals. In addition, the growth of protons and heavy ions therapy techniques, where neutrons are originated as parasitic radiation without therapeutic effect, makes necessary to measure neutron doses in patients. Consequently,...

    Go to contribution page
  32. Ildo Domingos Ufala (Universidade de Sรฃo Paulo), Maria da Penha Albuquerque Potiens (Universidade de Sรฃo Paulo/Institute for Energy and Nuclear Research)
    6/8/26, 6:47โ€ฏPM
    Other topics related to ionizing radiation
    Poster

    Radiological protection is a fundamental component of safety in the use of ionizing radiation, ensuring the protection of human health and the environment. The continuous expansion of radiation applications in medicine, industry, agriculture, and energy demands robust regulatory systems aligned with international recommendations, particularly those issued by the International Commission on...

    Go to contribution page
  33. Beatriz Garcia Fayos (Universitat Politรจcnica de Valรจncia)
    6/8/26, 6:49โ€ฏPM
    Environmental dosimetry and monitoring
    Poster

    Introduction
    Radon is a naturally occurring radioactive gas generated by the decay of uranium present in soils and rocks. It can infiltrate buildings through cracks and pores in construction materials or exhale from the materials themselves, posing a significant health risk and being one of the main causes of lung cancer. This study investigates wall coverings as a strategy to reduce...

    Go to contribution page
  34. Beatriz Garcia Fayos (Universitat Politรจcnica de Valรจncia), GUMERSINDO JESUS VERDU MARTIN (Universitat Politecnica de Valencia)
    6/8/26, 6:51โ€ฏPM
    Environmental dosimetry and monitoring
    Poster

    Introduction
    Prolonged exposure to indoor radon gas represents a public health problem, driving research on mitigation strategies and the modification of building materials to achieve low gas permeability towards indoor spaces. This study evaluates the radon shielding effectiveness of different common building materials used as interior wall claddings, both in their raw form and after...

    Go to contribution page
  35. Dr Rong-Jiun Sheu (National Tsing Hua University)
    6/9/26, 3:30โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    A national primary standard for Tc-99m activity was established at NRSL/INER in Taiwan using a self-developed 4ฯ€exโ€“ฮณ coincidence counting system. The system integrates a compact flow-type 4ฯ€ proportional counter with a thin NaI(Tl) detector optimized for the detection of low-energy internal conversion electrons and 140 keV ฮณ-rays. Detection efficiency was systematically varied through...

    Go to contribution page
  36. Ms Tsz-Yui Chan (Department of Medical Imaging and Radiological Sciences, Chang Gung University, Taoyuan, Taiwan)
    6/9/26, 3:32โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    Introduction: Proton minibeam radiation therapy (pMBRT) enhances normal tissue sparing through sub-millimetric beamlets that create high-dose peaks and low-dose valleys. While research often utilizes a single Bragg peak, limiting treatment depth, this work addresses clinical target coverage by developing a passive Spread-Out Bragg Peak (SOBP) system specifically for radiobiological research...

    Go to contribution page
  37. Ana Gabryele Moreira dos Santos, Noemi Aguiar Silva (Federal University of Sรฃo Paulo)
    6/9/26, 3:34โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    In
    2002, Martin Ebert proposed the theoretical concept of Intensity Modulated
    Brachytherapy, which uses brachytherapy sources that emit radiation anisotropically to
    achieve dose intensity modulation [1]. To perform the dosimetric tests, a phantom was
    constructed from an acrylic box filled with acrylate water gel and a 3D-printed inner box
    made of polylactic acid or PLA. This phantom...

    Go to contribution page
  38. GUMERSINDO JESUS VERDU MARTIN (Universitat Politecnica de Valencia)
    6/9/26, 3:36โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    Introduction

    Radiotherapy during pregnancy represents a clinical and radiological challenge, in which reliable fetal dose estimation is essential to balance maternal therapeutic benefit and fetal radiation risk. A fetal absorbed dose of 100 mGy is widely cited as a practical reference level in radiological protection guidance. Although analytical models and advanced simulations are used for...

    Go to contribution page
  39. Maria da Penha Potiens (Instituto de Pesquisas Energรฉticas e Nucleares)
    6/9/26, 3:38โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    This work focuses on the development of a specific metrology and dosimetry methodology for systems utilizing low-energy X-ray beams. The study is motivated by the increasing use of portable X-ray equipment and the lack of established dosimetry protocols for these systems, which are currently calibrated only by their manufacturers. The study's methodology involved the use of parallel-plate...

    Go to contribution page
  40. Dr. Ahmed Alanazi (Northern Border University)
    6/9/26, 3:40โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    Background: Positron Emission Tomography/Computed Tomography (PET/CT) plays a crucial role in diagnosing, staging, and monitoring head and neck malignancies. However, the combined radiation dose from both PET (e.g., 18F-FDG) and CT components raises concerns regarding patient exposure and long-term risks. Understanding and optimizing dose parameters, such as injected radiotracer activity, CT...

    Go to contribution page
  41. Prof. Lu-Han Lai (Department of Medical Imaging and Radiological Technology, Yuanpei University of Medical Technology, Hsinchu, TAIWAN)
    6/9/26, 3:42โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    Synchronous bilateral breast cancer (SBBC) requiring regional nodal irradiation (RNI) presents profound dosimetric challenges, particularly in sparing the heart and lungs. This study comprehensively evaluates the dosimetric impact of varying nodal irradiation targets using volumetric modulated arc therapy (VMAT) with two full arcs in hypofractionated regimens. Thirty SBBC patients were...

    Go to contribution page
  42. Dr Leandro Mariano (Federal Institute of Parana), Anna Luiza Malthez (Federal University of Technology โ€“ Paranรก)
    6/9/26, 3:44โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    Dosimetry employing normoxic polyacrylamide gel (nPAG) dosimeters is a promising tool for recording and evaluating three-dimensional (3D) dose distribution in clinical linear accelerators (LINACs). Also, nPAG dosimeters can evaluate several informations required in quality assurance in radiotherapy treatments with photon and electron beams, such as beam profile, flatness and symmetry....

    Go to contribution page
  43. Yu Fang Lin
    6/9/26, 3:46โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    Small and narrow cutout fields of electron beam are commonly used in keloid radiotherapy. However, they pose several dosimetric challenges, including lateral scatter disequilibrium, source occlusion. This study investigated physical dose distributions for small and narrow fields used in keloid and breast scar boost radiotherapy. We conducted measurements in an Elekta Versa HD linear...

    Go to contribution page
  44. Ms Anna Zampieri (Federal University of Sรฃo Paulo), Dr sonia tatumi (Federal University of Sรฃo Paulo)
    6/9/26, 3:48โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    Optically Stimulated Luminescence (OSL)-based dosimetry has emerged as a promising technique for radiation monitoring in medical, environmental, and occupational applications. In this study, the OSL properties of lithium magnesium phosphate materials doped with titanium (LiMgPOโ‚„:Ti) were investigated with the aim of optimizing sensitivity and dose-response linearity.Pure LiMgPOโ‚„ and samples...

    Go to contribution page
  45. Mrs Ana Laura Ramos Mitidiero (Postgraduate Program in Biomedical Engineering, Faculty of Electrical Engineering, Federal University of Uberlรขndia, PPGEB/UFU, Uberlรขndia, Brazil)
    6/9/26, 3:50โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    Gynecological intracavitary brachytherapy is a standard treatment for cervical and endometrial malignancies. During applicator insertion, such as vaginal cylinders, air gaps often form between the applicator and vaginal mucosa [1]. These heterogeneities introduce uncertainties based on size and location, potentially altering dosimetric distribution [2]. Since commercial Treatment Planning...

    Go to contribution page
  46. Mr Felipe Beraldo da Cruz (Postgraduate Program in Biomedical Engineering, Faculty of Electrical Engineering, Federal University of Uberlรขndia, PPGEB/UFU, Uberlรขndia, Brazil)
    6/9/26, 3:52โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    External radiotherapy is one of the main treatment modalities for brain tumors. However, irradiation of structures adjacent to the target volume is unavoidable, particularly in procedures such as whole-brain radiotherapy (WBRT). Among the most frequent adverse effects is localized alopecia, resulting from dose deposition in the scalp [1]. Although a well-established correlation exists between...

    Go to contribution page
  47. Mrs Ingrid Cristina dos Santos Silva (Postgraduate Program in Biomedical Engineering, Faculty of Electrical Engineering, Federal University of Uberlรขndia, PPGEB/UFU, Uberlรขndia, Brazil)
    6/9/26, 3:54โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    Tongue cancer accounts for nearly 20,000 new cases projected for 2026, with a higher incidence in men [1]. Both teletherapy and brachytherapy are established treatment options. In this work, Monte Carlo simulations were used to investigate and compare the dosimetric characteristics of these two approaches. The absorbed dose in the adult male mesh-type virtual anthropomorphic phantom [2], was...

    Go to contribution page
  48. Mr Victor Luiz Ossick Evangelista (Postgraduate Program in Biomedical Engineering, Faculty of Electrical Engineering, Federal University of Uberlรขndia, PPGEB/UFU, Uberlรขndia, Brazil)
    6/9/26, 3:56โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    Hepatocellular carcinoma (HCC) accounts for more than 90% of primary liver tumors and is strongly associated with cirrhosis [1]. It is among the most incidental and lethal neoplasms worldwide, with low five-year survival rates due to late diagnosis and complex management. Risk factors include chronic viral hepatitis and alcoholic and metabolic liver diseases [2]. Hepatic radioembolization with...

    Go to contribution page
  49. Mrs Fernanda Quadros Fuzato (Postgraduate Program in Biomedical Engineering, Faculty of Electrical Engineering, Federal University of Uberlรขndia, PPGEB/UFU, Uberlรขndia, Brazil)
    6/9/26, 3:58โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    Breast cancer is the most frequently diagnosed cancer among women, with over 2 million new cases annually [1]. In advanced-stage cases, many patients undergo mastectomy followed by reconstruction with tissue expanders. These devices may remain in the patientโ€™s body for several weeks, during which post-mastectomy radiotherapy is usually initiated. However, due to the presence of metallic...

    Go to contribution page
  50. Adriรกn Dรญaz Comeche (Universitat Politรจcnica de Valรจncia)
    6/9/26, 4:00โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    The generation of secondary neutron fields in proton therapy treatments is a major concern because of the exposure of patients and staff to incidental dose. Even if current Pencil Beam Scanning techniques minimize neutron production compared to passive scattering, the risk of secondary cancers due to stray neutron doseโ€”especially in paediatricsโ€™โ€”remains non-negligible. Many studies have...

    Go to contribution page
  51. Prof. Abdelmoneim Sulieman (King Faisal Specialist Hospital and Research Center)
    6/9/26, 4:02โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    Cardiac computed tomography (CCT) is widely used for non-invasive coronary artery assessment; however, it involves direct irradiation of the anterior chest, where breast tissue is located. Therefore, breast tissue receives a relatively higher absorbed dose compared with many other CT examinations that may contribute to cancer risks. This study evaluated patient radiation doses, effective doses...

    Go to contribution page
  52. Cassio Vilela Komatsu (Postgraduate Program in Biomedical Engineering, Faculty of Electrical Engineering, Federal University of Uberlรขndia, PPGEB/UFU, Uberlรขndia, Brazil), Mr Felipe Beraldo da Cruz (Postgraduate Program in Biomedical Engineering, Faculty of Electrical Engineering, Federal University of Uberlรขndia, PPGEB/UFU, Uberlรขndia, Brazil)
    6/9/26, 4:04โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    The use of the surgical C-arm in orthopedic procedures is well established due to its ability to provide real-time fluoroscopic imaging, contributing to improved surgical precision and reduced operative time. However, scattered radiation represents a potential occupational risk to the medical staff, making it essential to understand its magnitude and angular distribution. This study evaluated...

    Go to contribution page
  53. Dr Leticia Franรงa Fiuza Bacelar Bacelar, Dr Maria da Penha Albuquerque Potiens
    6/9/26, 4:06โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    Introduction:Chest computed tomography (CT) is widely used in clinical practice, particularly in emergency settings and in the follow-up of respiratory diseases. The progressive increase in the use of this diagnostic method, intensified during the COVID-19 pandemic, has raised concerns regarding the cumulative exposure of the population to ionizing radiation and its potential public health...

    Go to contribution page
  54. Yu Chieh Lin (Chang Gung Memorial Hospital at Linkou, Taiwan)
    6/9/26, 4:08โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    Purpose: To evaluate the impact of different breast implant brands and their volumetric proportions on mean glandular dose (AGD) and Signal-to-Noise Ratio (SNR) in digital mammography.
    Methods: Three types of implantsโ€”Motiva Ergonomixยฎ, MENTORโ„ข MemoryGelโ„ข, and Natrelleยฎ Silicone-Filled Implantsโ€”were involved in the study. Implants were placed with CIRS BR3D phantoms to simulate compression...

    Go to contribution page
  55. Mrs Ana Laura Burin (IPEN/USP)
    6/9/26, 4:10โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    Accurate dosimetric assessment in anatomically complex regions such as the vertebral column is essential for advancing radiotherapy and brachytherapy strategies, particularly in the management of bone metastases. This study presents the development of a computational phantom of the vertebral column, constructed from DICOM imaging data and incorporating a localized tumor volume. The phantom was...

    Go to contribution page
  56. Ping-Jung Hsieh (New Taipei Municipal Tucheng Hospital (Chang Gung Medical Foundation), Taiwan)
    6/9/26, 4:12โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    Introduction: Monitoring radiation dose distribution is essential for patient safety during fluoroscopically guided interventions. While Air Kerma (AK) is the standard machine reported metric for X-ray intensity, it does not fully characterize the actual dose absorbed at varying tissue depths. This study evaluates the correlation between AK and patient-specific dose equivalents, Hp(0.07) for...

    Go to contribution page
  57. Ms Yu-Hsuan Chen (Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan)
    6/9/26, 4:14โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    BNCT for large-volume oral cavity cancer challenges the balance between maximizing tumour dose and protecting organs at risk. Single-field irradiation often fails to achieve deep-dose coverage due to entry angle constraints. This study evaluates the dosimetric impact of single-field versus two-field configurations. A retrospective analysis was performed for oral cavity cancer (GTV 96.46 cc)...

    Go to contribution page
  58. Abdullah Almujally (Biomedical Physics Department, King Faisal Specialist Hospital and Research Center)
    6/9/26, 4:16โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    Medical exposure to ionizing radiation during interventional procedures can lead to stochastic consequences, such as an increased risk of cancer, and deterministic tissue responses when threshold levels are surpassed. Cardiac catheterization procedures, including percutaneous coronary intervention (PCI), are commonly conducted in catheterization laboratories for many clinical indications and...

    Go to contribution page
  59. Tsz-Yui Chan (Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University)
    6/9/26, 4:18โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    Range uncertainty remains a major limitation in proton therapy because treatment planning depends on CTโ€toโ€stoppingโ€power conversion, which introduces an intrinsic uncertainty of approximately 3.5%. Discrete range modulation (DRM) proton radiography (pRG) provides a projection-based estimate of the water equivalent path length (WEPL) by delivering a sequence of discrete proton energies and...

    Go to contribution page
  60. Dr Amjad ALYAHYAWI (Diagnostic Radiology Department, College of Applied Medical Sciences, University of Hail,Hail.)
    6/9/26, 4:20โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    The mammary gland, originating from the ectoderm, is primarily responsible for milk production and, in humans, also has aesthetic and psychosocial importance. Breast size and contour vary widely among individuals, and complete symmetry is uncommon. Anatomically, the gland is composed of lobules that produce milk, connected by ducts that drain toward the nipple, and supported by fibrous stroma...

    Go to contribution page
  61. Jacco de Pooter
    6/9/26, 4:22โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    The FLASH-DOSE project addresses the urgent need for reliable and metrologically traceable reference dosimetry for FLASH radiotherapy using ultra-high proton dose rates (UHDR) and ultra-high pulsed electron beams (UHDPP). Preclinical studies have demonstrated the so-called FLASH effect, which can reduce damage to healthy tissues by up to 40% while maintaining antitumor effectiveness. However,...

    Go to contribution page
  62. Ms Yu-Hsuan Chen (Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan)
    6/9/26, 4:24โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    In two-field BNCT for oral cavity cancer, blood boron concentration estimates are required before treatment to generate dose plans. Understanding how this parameter affects dose distribution and irradiation time is essential for robust planning and treatment-day calibration. This study quantified these effects at 30 versus 40 ppm in a two-field BNCT plan for a large-volume tumour. A...

    Go to contribution page
  63. Hugo Schelin (Federal University of Technology - Parana)
    6/9/26, 4:26โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    Conventional radiography remains essential in pediatric imaging of the chest, skull, paranasal sinuses, pelvis, and abdomen. However, inadequate clinical justification and repeated exposures may increase unnecessary radiation doses in radiosensitive populations. This study evaluated the correlation between clinical indications, repetition rates, and entrance surface air kerma (Ka,e) in...

    Go to contribution page
  64. Kwo-Ping Chang (Department of Medical Imaging and Radiological Sciences, Tzu-Chi University, Taiwan.)
    6/9/26, 4:28โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    Barium sulfate (BaSOโ‚„) contrast medium is widely used as a radiographic agent in gastrointestinal imaging. By coating and adhering to the gastrointestinal mucosa, it enhances radiographic contrast, facilitating improved visualization and the diagnosis of ulcers, tumors, and obstructions. This study aimed to assess the effects of barium sulfate contrast medium on dose evaluation in the linear...

    Go to contribution page
  65. Ms Rasil Almuhanna (Princess Nourah bint Abdulrahman University), Ms renad alsulaiman (Princess Nourah bint Abdulrahman University)
    6/9/26, 4:30โ€ฏPM
    Dosimetry and radiation protection in medicine and biology
    Poster

    Shielding against ionizing radiation intends to protect workers, and public against ionizing radiation exposure, and prevents it adverse effect. Shielding designs are based on calculated assumptions (workload, use factor, occupancy, distance, beam quality). After installation and during operation, facilities must verify that radiation levels outside the room remain within acceptable limits and...

    Go to contribution page
  66. Dr JESSICA MOSQUEIRA-YAURI (UNSA)
    6/10/26, 3:30โ€ฏPM
    Environmental dosimetry and monitoring
    Poster

    Jessica Mosqueira-Yauri$^1$, Fanny Ramos-Chui $^1$ ,Edwar A. Canaza$^1$, Jorge Ayala-Arenas $^1$, Nilo F. Cano$^2$

    $^1$Universidad Nacional de San Agustรญn, Arequipa, Perรบ
    $^2$Universidade Federal de Sรฃo Paulo, SP, Brazil
    The thermoluminescence (TL) of a material depends on the synthesis process, the percentage and type of dopant used, and the impurities present in its crystal structure. ...

    Go to contribution page
  67. Abdelmoneim Sulieman (Biomedical Physics Department, King Faisal Specialist Hospital and Research Center)
    6/10/26, 3:32โ€ฏPM
    Dosimetry and radiation protection in nuclear installations and at accelerators
    Poster

    Cyclotron facilities are essential for the production of medical radionuclides, including ยนโธF, ยนยนC, ยนยณN, and ยนโตO, which are widely used in positron emission tomography (PET) imaging. However, cyclotron operation involves high-energy particle acceleration and target irradiation, generating complex radiation fields and potential occupational hazards. Therefore, continuous monitoring of...

    Go to contribution page
  68. Ana Jambrina (VTT Technical Research Centre of Finland Ltd)
    6/10/26, 3:34โ€ฏPM
    Dosimetry and radiation protection in nuclear installations and at accelerators
    Poster

    The extended operation of many pressurized water reactors now exceeds their original design lifetimes, elevating the importance of stringent safety requirements. A central consideration in evaluating the feasibility of further lifetime extension is the accurate assessment of neutronโ€‘induced embrittlement in the reactor pressure vessel (RPV), as this degradation mechanism directly limits...

    Go to contribution page
  69. Jaroslav Klusoลˆ (Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague)
    6/10/26, 3:36โ€ฏPM
    Environmental dosimetry and monitoring
    Poster

    The Faculty of Nuclear Sciences and Physical Engineering CTU in Prague (FNSPE) has been providing periodic monitoring of the impact of the operation of the NPP Temelin on the environment since 2000 (including the zero state). Monitoring is conducted at 29 selected reference points within an area with radii of 2, 5, 10, and 20 km around the NPP. Samples of Schreiber's moss, forest humus, pine...

    Go to contribution page
  70. Vรกclav ล tฤ›pรกn (Czech Technical University in Prague, Faculty of Nuclear Sciences and Physical Engineering)
    6/10/26, 3:38โ€ฏPM
    Environmental dosimetry and monitoring
    Poster

    Zadnรญ Chodov is a uranium mine in ฤŒeskรฝ les, some 130 km west from Prague and less than six kilometers from the German border. With 4152 tons of uranium mined between its discovery in 1952 and closing of the mine in 1992, this was the sixth largest deposit in Czech Republic and is a Category III workplace according to the Czech legislation.

    Flooding of the mine started in February 1993...

    Go to contribution page
  71. Ms Christina Antoniadou (ELI Beamlines, ELI ERIC)
    6/10/26, 3:40โ€ฏPM
    Dosimetry and radiation protection in nuclear installations and at accelerators
    Poster

    High-power laser facilities generate ultra-short (sub-nanosecond), ultra-high dose-rate particle fields with instantaneous dose rates reaching $10^8 - 10^{10}$ Gy/s and complex mixed particle compositions including neutrons, photons, electrons, and protons. Accurate dosimetry under these conditions remains a major challenge due to detector saturation, recombination effects, limited temporal...

    Go to contribution page
  72. Vรกclav ล tฤ›pรกn (Czech Technical University in Prague, Faculty of Nuclear Sciences and Physical Engineering)
    6/10/26, 3:42โ€ฏPM
    Environmental dosimetry and monitoring
    Poster

    Public open caves belong to underground workplaces with radon. The average annual radon concentration in caves in the Czech Republic reaches up to 2500 Bqยทm$^{-3}$. The methodology for estimation of effective dose (E) from radon for the cave guides is based on integral radon activity concentration measurement (using trace detectors RamaRn) and evidence of working hours spent in the underground...

    Go to contribution page
  73. Tomรกลก Trojek (Czech Technical University in Prague)
    6/10/26, 3:44โ€ฏPM
    Environmental dosimetry and monitoring
    Poster

    The identification of uranium in samples does not have to rely solely on spectrometry of ionizing radiation produced within its radioactive decay. More effective methods could be based on the stimulated emission of characteristic X-ray radiation of uranium in a sample using a suitable radiation source. In X-ray fluorescence analysis (XRF) performed with benchtop devices, these sources could be...

    Go to contribution page
  74. Andrej Mojzeลก (Comenius University in Bratislava)
    6/10/26, 3:46โ€ฏPM
    Environmental dosimetry and monitoring
    Poster

    The geological structure of the Western Carpathians in Slovakia is very diverse and reflected in natural radioactivity. Slovakia is relatively rich in mineral, as well as deposit-forming occurrences of uranium and thorium ores. Likewise, many rock formations contain potassium in their basic matrix. The origin of the increased surface radioactivity may lie either in the lithogeochemical...

    Go to contribution page
  75. Cristina Trull-Hernandis (Universitat Politรจcnica de Valรจncia)
    6/10/26, 3:48โ€ฏPM
    Environmental dosimetry and monitoring
    Poster

    Radon is a radioactive gas that can be present naturally in environments either in the soil, dissolved in their waters or in the air phase of enclosed areas. In spaces with large bodies of radon-bearing water, the radon dissolved can be released from the water to indoor air. Due to the risks derived from the inhalation of radon and its progeny, radon levels must be controlled in areas with...

    Go to contribution page
  76. Mr Wei-Han Chu (National Atomic Research Institute/National Tsing Hua University), Prof. Rong-Jiun Sheu (National Tsing Hua University)
    6/10/26, 3:50โ€ฏPM
    Environmental dosimetry and monitoring
    Poster

    Current metrological frameworks exhibit a significant traceability gap between ambient background levels and standard calibration intensities, complicating the characterization of radiation detectors at low dose rates. This study addressed this limitation by developing an environmental-level air kerma rate calibration system using a Co-60 source with lead attenuators (3.5โ€“9.0 cm) in compliance...

    Go to contribution page
  77. Domen Govekar (Joลพef Stefan Institute)
    6/10/26, 3:52โ€ฏPM
    Dosimetry and radiation protection in nuclear installations and at accelerators
    Poster

    Activated water is a significant radiation source in DT fusion-oriented research environments, where neutron-activated cooling and auxiliary water systems can produce mixed-energy gamma fields that complicate measurement and dose assessment. Separating low- and high-energy dose contributions is still challenging. In this work, incremental lead shielding is applied as a controlled,...

    Go to contribution page
  78. Hugo Schelin (Federal University of Technology - Parana)
    6/10/26, 3:54โ€ฏPM
    Environmental dosimetry and monitoring
    Poster

    Indoor radon is a major contributor to natural radiation exposure and is recognized as the second leading cause of lung cancer worldwide. It originates from the decay of uranium and thorium naturally present in soil and building materials and can enter buildings through cracks and structural openings. This study aimed to measure indoor radon concentrations in residences located in Carambeรญ and...

    Go to contribution page
  79. Aina Noverques Medina, Cristina Trull-Hernandis (Universitat Politรจcnica de Valรจncia)
    6/10/26, 3:56โ€ฏPM
    Environmental dosimetry and monitoring
    Poster

    Understanding the interaction between radon, its short-lived progeny, and respiratory protective equipment such as face masks (surgical and FFP3) is essential to improve the assessment of inhalation exposure in environments with elevated radon levels. In particular, distinguishing between the behavior of primary radon gas and particle-bound progeny is key to evaluating the effectiveness of...

    Go to contribution page
  80. Sita Gandes Pinasti (SCK CEN / ULB)
    6/10/26, 3:58โ€ฏPM
    Dosimetry and radiation protection in nuclear installations and at accelerators
    Poster

    Personal neutron dosimetry in nuclear installations is challenging due to the energy and angle dependence of detector response. When personal dosimeters calibrated in standard reference fields are used in workplace fields with different spectral and angular characteristics, systematic biases in dose estimates can arise. Simulated workplace fields (SWFs) are therefore essential for reproducing...

    Go to contribution page
  81. Francesco Teodori (University of bologna)
    6/10/26, 4:00โ€ฏPM
    Environmental dosimetry and monitoring
    Poster

    A multipurpose health physics code was developed to provide a comprehensive and reliable computational framework for the assessment of radiation dose and associated health risk to individuals and populations. The system supports both retrospective analyses (post-event reconstruction of exposure and dose) and prospective evaluations (predictive assessments for planned or hypothetical release...

    Go to contribution page
  82. Hugo Schelin (Federal University of Technology - Parana)
    6/10/26, 4:02โ€ฏPM
    Environmental dosimetry and monitoring
    Poster

    Radon (222Rn) is a naturally occurring radioactive gas that represents a significant source of internal exposure to ionizing radiation. In regions where groundwater is used for human consumption, radon dissolved in well water may contribute to ingestion dose and indoor air contamination. This study aimed to evaluate radon concentrations in well water, rocks, and soil samples collected in the...

    Go to contribution page
  83. Martina Luลพovรก (Nuclear Physics Institute CAS, ล˜eลพ, Czech Republic)
    6/10/26, 4:04โ€ฏPM
    Environmental dosimetry and monitoring
    Poster

    Measurements of secondary cosmic radiation in the lower atmosphere provide important insight into particle acceleration processes in thunderstorms and high-energy atmospheric physics. Observations performed with the MOSAIC detector, a compact four-layer silicon strip tracking system designed for directional measurements of charged particles, will be reported.

    The detector has been deployed...

    Go to contribution page
  84. Ondล™ej Ploc (Department of Radiation Dosimetry, Nuclear Physics Institute of the Czech Academy of Sciences, Na Truhlรกล™ce 39/64, Prague, 180 00, Czechia)
    6/10/26, 4:06โ€ฏPM
    Environmental dosimetry and monitoring
    Poster

    This study investigates the radiation field generated during high-voltage switching impulse discharges, extending our prior work that confirmed photon/electron and neutron radiation components for atmospheric impulses (1.2/50 ฮผs waveform) using passive detectors. While the atmospheric impulse waveform has been extensively studied in the context of lightning discharge simulation, the switching...

    Go to contribution page
  85. Martin Kaschner (KDAIZ, FJFI, ฤŒVUT v Praze)
    6/10/26, 4:08โ€ฏPM
    Environmental dosimetry and monitoring
    Poster

    Gas transport within permeable waste rock may result in the exhalation of hazardous gases, such as radon-rich or oxygen-deficient air, driven by seasonal stack-effect airflow. While the airflow regime can be identified by differential pressure monitoring or ground surface temperature analysis, characterizing the spatial heterogeneity of emissions across an entire landform remains a significant...

    Go to contribution page
  86. Monika Mรผllerovรก (Fakulta matematiky, fyziky a informatiky, Univerzita Komenskรฉho v Bratislave)
    6/10/26, 4:10โ€ฏPM
    Environmental dosimetry and monitoring
    Poster

    Between years 2015 and 2026 several indoor radon surveys in selected Slovak kindergartens were realized using passive track detectors with three months exposure. In total 61 kindergartens were monitored, in 37 of them one-year long survey was conducted and in 27 kindergartens also continuous monitoring was performed, at least during one three-month exposure of passive detectors. Annual average...

    Go to contribution page
  87. Mr Vรกclav Prochรกzka
    6/10/26, 4:12โ€ฏPM
    Environmental dosimetry and monitoring
    Poster

    Massic activity of Cs-137 has been measured in homogenized dried fronds of the fern Athyrium filix-femina. Samples were collected in 2005 and represent 35 biomonitoring plots in coniferous (prevalently spruce) forests across the Czech Republic. We combined the results with some data from the same sites partly presented in previous publications, including contents of stable cesium (Cs-133) in...

    Go to contribution page
  88. Yu-Tien Tsai (National Atomic Research Institute)
    6/10/26, 4:14โ€ฏPM
    Dosimetry and radiation protection in nuclear installations and at accelerators
    Poster

    To support the establishment of a future 30โ€“70 MeV proton irradiation facility and to facilitate experiment planning for semiconductor irradiation experiments and radiobiology studies, this work develops a beam evaluation framework that links beam characteristics to application-oriented irradiation conditions prior to facility operation. The framework establishes physical baselines by...

    Go to contribution page
  89. Dr Eva Domรฉnech (Universitat Politecnica de Valencia. Food UPV)
    6/10/26, 4:16โ€ฏPM
    Environmental dosimetry and monitoring
    Poster

    Extreme weather events, such as the isolated high-level depressions (DANA) in Valencia in October 2024, may result in significant erosion and soil structural degradation. This study presents the results of the assessment of the impact of the DANA on the natural radiological levels of agricultural soils of citrus fields in the Valencia region. The natural radioactivity levels in these soils,...

    Go to contribution page
  90. Anna Luiza Malthez (Federal University of Technology โ€“ Paranรก)
    6/10/26, 4:18โ€ฏPM
    Dosimetry and radiation protection in nuclear installations and at accelerators
    Poster

    The micro X-ray computed tomography is a non-destructive 3D imaging technique, being especially interesting for characterizing materials opaque to visible light, as minerals and biological samples. Conventional equipment (benchtop, medical, or industrial tomographs) offer limited spatial resolution of a few tens of micrometers for small samples (a few millimeters), and measurements are taken...

    Go to contribution page
  91. Ondล™ej Koล™istka
    6/10/26, 4:20โ€ฏPM
    Environmental dosimetry and monitoring
    Poster

    Variations in radon concentration in underground environments have long been investigated as potential indicators of geodynamic processes. Changes in tectonic stress may open new migration pathways for subsurface gases, leading to measurable anomalies in radon concentration. Such anomalies have been reported prior to several seismic events, suggesting that radon monitoring could contribute to...

    Go to contribution page
  92. Joanna Rocznik (Silesian University of Technology)
    6/10/26, 4:22โ€ฏPM
    Environmental dosimetry and monitoring
    Poster

    Luminescence dating accuracy relies on precise determination of the total dose rate ($D_r$). While alpha and beta radiation effects are highly localised, gamma radiation forms a complex, continuous field influenced by the heterogeneous distribution of radionuclides throughout a sediment profile. Standard dosimetry often overlooks these spatial fluctuations, potentially leading to age...

    Go to contribution page
  93. Helena Velyฤkovรก (Nuclear Physics Institute of the Czech Academy of Sciences)
    6/10/26, 4:24โ€ฏPM
    Environmental dosimetry and monitoring
    Oral Presentation

    The Gamma Spectrometry of Thunderstorm Radiation Observatory Network (GASTRON) is a distributed system of ground-based gamma spectrometers dedicated to the detection and characterization of high-energy radiation phenomena associated with thunderstorms, including Terrestrial Gamma-ray Flashes (TGFs) and Thunderstorm Ground Enhancements (TGEs), also called gamma-ray glows. Building on previous...

    Go to contribution page
Building timetable...